• WB-200 is a level 2, Method A water-washable fluorescent penetrant for inspecting castings, extrusions and similar parts.
  • RC-77 is a level 4, Method B & D non-water washable fluorescent penetrant for inspecting castings, extrusions and similar parts
  • RC-65 is a level 3, Method B & D non-water washable fluorescent penetrant for inspecting castings, extrusions and similar parts.
  • RC-50 is a level 2, Method B and D non-water washable fluorescent penetrant for inspecting castings, extrusions and similar parts.
  • Applied by immersion, spray, or wipe on. Low in sulfur and halogens and is safe for use on all metal surfaces.
  • Applied by immersion, spray, or wipe on. Low in sulfur and halogens and is safe for use on all metal surfaces.
  • FP-923 is used for the detection of fine cracks, porosity, and through leaks on metals, composites, synthetic materials, and some plastics.
  • Applied by immersion, spray, or wipe on. Low in sulfur and halogens and is safe for use on all metal surfaces.
  • FP-922 is used for the detection of fine cracks, porosity, and through leaks on metals, composites, synthetic materials, and some plastics.
  • FP-921 is used for the detection of fine cracks, porosity, and through leaks on metals, composites, synthetic materials, and some plastics.
  • FLP-1 is a special water based fluorescent penetrant concentrate designed for through leak testing and general metal working surface flaw detection.
  • ER-83A is a hydrophilic emulsifier used diluted with water to emulsify Sherwin’s non-water washable penetrants.
  • DP-51 is water washable visible penetrant used to locate cracks, laps, pores, lack of bonding, and similar surface flaws.
  • DP-50 is water washable visible penetrant used to locate cracks, laps, pores, lack of bonding, and similar surface flaws.
  • DP-40 is a non-water washable visible penetrant used to locate cracks, laps, pores, lack of bonding, and similar surface flaws.
  • Description: HM-604 is a level 3, Method A water washable fluorescent penetrant for inspecting castings, extrusions and similar parts.
  • Widely used in aerospace on magnesium, aluminum and titanium castings and extrusions. More sensitive than HM-3A. Also in spray cans.
  • Solvent removable visible penetrant testing kits with SKL-SP2, SKD-S2 and SKC-S for portable dye penetrant testing for job sites and field inspections
  • DR-62 Cleaner-Remover is used in the penetrant process to remove excess, non water-washable penetrants from part surfaces, e.g., Sherwin DP-40 Dye Penetrant (visible red) and Sherwin RC-65 and RC-77 Fluorescent Penetrants. It is a manual “wipe on” and “wipe off” material and, consequently, recommended for small areas.
  • DR-60 Cleaner-Remover is used in the penetrant process to remove excess, nonwater-washable penetrants from part surfaces, e.g., Sherwin DP-40 Dye Penetrant (visible red) and Sherwin RC-65 and RC-77 Flourescent Penetrants. It is a manual “wipe on” and “wipe off” material and, consequently, recommended for small areas.
  • ER-85 is a Method B emulsifier. It does not require a prewash step and is used at full strength. It meets the requirements for low sulfur, low halogen, and low-sodium.
    • As a pre-cleaner it is sprayed directly on the test surface.
    • As a penetrant remover it is sprayed onto wiping media and then the penetrant wiped from the surface. The remover should not be sprayed directly on to the test surface to remove the excess penetrant as the sensitivity will be impaired.
    • A cotton swab is moistened with R-504 and suspected indications are lightly wiped from the surface. The inspector can evaluate the indication by the rate of penetrant bleed back. The rapid drying of R-504 is ideal for this application as it does not blur the indication.
    • The aerosol comes with a spray tube that facilitates pin point application which is ideal for cleaning the star indications on TAM panels.
    • Contains flammable solvents and should not be used in confined spaces or near open flames or sparks.
    R-504 is ideal for storing penetrant test panels in.
    Available as 1 pint (0.5 L), 1 gallon (3.8 L), 5 gallon (18.9 L), 55 gallon (208 L)
    • As a pre-cleaner it is sprayed directly on the test surface.
    • As a penetrant remover it is sprayed onto wiping media and then the penetrant wiped from the surface.
    • The remover should not be sprayed directly on to the test surface to remove the excess penetrant as the sensitivity will be impaired.
    • Contains flammable solvents and should not be used in confined spaces or near open flames or sparks.
    R-503 is ideal for storing penetrant test panels in. The spray tube supplied with the aerosols is an effective way to clean out the star bust cracks on TAM panels.
  • R-502 finds wide use in field weld and weld repair inspection. It is used in the inspection of refinery processing equipment that is at elevated temperatures, speeding up the inspection process time by eliminating the cool down required for standard penetrant processing. Protective gloves should be worn while working on hot surfaces to avoid burns.
    Available as 1 pint (0.5 L), 1 gallon (3.8 L), 5 gallon (18.9 L)